• Simplicity and intuitive operation
  • Non-speaking device
  • Suitable for: homes for the elderly, homes with special needs, long-term care facilities, hospices, hospitals

The alarm device provides patients with the ability to easily summon staff whenever needed. With the simple push of a button, a signal is sent to alert staff immediately and allow them to intervene quickly.

Signalling device
Entrance

Entrance Terminal ET-07 IP

Entrance Terminal ET-07 IP

Description

  • Provides a loudspeaker connection to the main terminal. 
  • It is mainly placed at the entrance door to the department as a doorbell. 
  • In conjunction with a card reader, it creates a simple access system.
  • Possibility of connecting an LED signal light.  
  • The element is not intended for outdoor use!
  • As with all other elements of the system, it can only be used indoors (unless otherwise stated).
  • Enables connection to an IP camera and transmission of images from the entrance door to the main terminal.
  • Antibacterial surface (silver admixture in the plastic material)

Technical specifications

Dimensions: 151 x 82 x 23 mm

Weight: 207g.

Power supply: 24V

Maximum power consumption: 1,8W.

IP camera

IP camera

Description

  • After activating a call from a specific location, it allows the transmission of an unrecorded online image to the main terminal. The most common is located at the entrance door to the department. 
  • It is mounted on the wall or ceiling using a custom bracket.
  • A commercial PoE adapter ( max 15W) connected to 230V/50Hz is usually used for power supply
  • Alternatively, a 24V system power supply or a 12V DS module can be used, but it depends on the capabilities of the specific camera type. 

Technical specifications

Lens: 3,8mm

30 frames per second

Dimensions: 92.6 x 92.6 x 79.5 mm

Weight: 500g.

Power supply: 230V (12V)

Maximum power consumption: 15W.

Corridor

Corridor lamp LED CL

Corridor lamp LED CL

Description

  • The signal lamp has three different colored lights, signaling in connection with the room terminal the status and type of call at the given location.
  • It is placed visibly in the hallway above the door of each bed room or separate bathroom and toilet. (Note that the light is not normally placed above the service room door).
  • Antibacterial surface (silver admixture in the plastic material)

Technical specifications

Dimensions: 82 x 82 x 56 mm

Weight: 105g.

Power supply: 24V

Maximum power consumption: 1,5W.

Directional light LED DL IP

Directional light LED DL IP

Description

  • Configuration settings are made using standard configuration software.
  • Possibility of gluing directional arrows (not part of the luminaire).
  • It is used in cases of a fragmented floor plan of the department, when the nursing staff from the central station (corridor) cannot see all the lights above the room.
  • The direction indicator lamp is then placed visibly and "repeats" the light signals of the lamps that are not visible in the given direction.

Technical Specification

Dimensions: 82 x 82 x 56 mm

Weight: 135g.

Power supply: 24V

Maximum power input: 1,5W.

Patient's room

Patient's bed connection with holder BC-01H IP

Patient's bed connection with holder BC-01H IP

Description

  • It is connected to the room terminal and provides the the connection to the patient button (no speech unit PU-01).
  • It enables the activation of an emergency call (no speech) from the bed.
  • It is most often installed in ICU rooms, where the staff is always present and there is no speech function with the patient requested.
  • When using a patient socketwith print holder. (no speech), a connection to a room call terminal is recommended to maintain call functions throughout the room.
  • It is thus easy to create a signaling system with a connection to a full-fledged IP communication system.
  • Patient drawer with print holder. (no call) is used to hang up and connect only the patient button (no call).The connector for connecting the patient button is in the holder position from the bottom of the element.

Technical Specification

Dimensions: 82 x 82 x 39 mm

Weight: 80g.

Patient's bed connection BC-01

Patient's bed connection BC-01

Description

  • It is connected to the room terminal and provides the the connection to the patient button (no speech unit PU-01).
  • It enables the activation of an emergency call (no speech) from the bed.
  • It is most often installed in ICU rooms, where the staff is always present and there is no speech function with the patient requested.
  • When using a patient socket with print holder (no speech), a connection to a room call terminal is recommended to maintain call functions throughout the room.
  • It is thus easy to create a signaling system with a connection to a full IP communication system.
  • It is used in bed rooms, where there are wall installation ramps and a socketis mounted directly on this ramp.The connector for connecting the patient terminal is from the front of the element.A separate bracket must be used to hang the patient button (without a call) on the wall.

Technical Specification

Dimensions: 82 x 82 x 23 mm

Weight: 75g.

Patient's unit (no speech) PU-01 IP

Patient's unit (no speech) PU-01 IP

Description

  • This element is a basic variant of the patient button, providing only an emergency button call to nurse without speech.
  • It does not allow any conversation with her sister or listening to an entertainment program.
  • Connects to the patient socket (no call). It is most often used in ICU rooms,where the staff is always present and no conversational connection with the patient is required.
  • It is also suitable for installation in nursing homes for clients with reduced orientation in space.
  • It contains only one large red button (backlit at night) with the nurse symbol.
  • The function of the button is programmable, but most often it fulfills the function of an emergency call from the bed.
  • The connection of the patient button (without a call) to the patient socket (without a call) is solved by a straight cord with a pull-out connector.
  • This ensures safe disconnection of the elements during strong pullingin all directions without compromising the functionality or service life of the equipment.
  • Another option is to connect using a twisted cord.
  • NOTE: When ordering a patient button (no call), the type of cable required must be specified!

Technical Specification

Dimensions: 82 x 82 x 23 mm

Weight: 75g

Power supply: 3-24V

Maximum power input: 1W

Room terminal RT-07 IP

Room terminal RT-07 IP

Description

  • It does not contain a loudspeaker and it is not possible to make loud voice calls from it, or to receive business or central announcements.
  • It is used, for example, in rooms: separate bathrooms, toilets, cleaning rooms, etc.
  • After registration of personnel with the appropriate button, the reception of optical and acoustic information about the origin of any type of call to the department is activated.
  • It enables the distinction between the registration of professional and nursing staff (green and yellow sister).
  • End all types of calls from the room, without having to answer the callat the main terminal.
  • Opening the lock at the entrance door to the department. This feature is not offered by default. It is necessary to inform the equipment supplier about the requirements for the possibility of opening the locks in advance.
  • It provides the connection of up to 5 external elements (for example non-speech patient units or toilet buttons/pull cords
  • Connectable elements are, for example, emergency call buttons and handles, a patient socket without a call or an interfering button.
  • Allows connection of an LED signal light.

Technical Specification

Dimensions: 82 x 82 x 23 mm

Weight: 135g

Power supply: 24V

Maximum power input: 1,8W

Room terminal with RT-07CR IP card reader

Room terminal with RT-07CR IP card reader

Description

  • DescriptionIt includes an integrated RFID card reader.
  • The integrated RFID reader enables staff registration in the room with direct entryto the system history (records the name of the participant/card registration number, date, time, location of the place). This makes it possible to monitor the movement of staff in the department.
  • It is mainly used in patient rooms.
  • After personnel registration with the appropriate button, optical and acoustic reception is activatedinformation about the origin of any kind of call to the department.
  • In the registration mode, the "presence" of the nurse enables the reception of voice calls.
  • It enables "surveillance" over departments even in rooms other than the main terminal.
  • It provides the termination of all types of calls from the given room, without the need to accept the callto the main terminal.
  • It does not allow the distinction of registration of professional and nursing staff (green nurse only).
  • It ensures the opening of the lock at the entrance door to the department. This function is not offered as standard, so it is necessary to inform the equipment supplier about the requirements for the possibility of opening the locks in advance.
  • It provides the connection of up to 5 external activation elements with the possibility of programming up to two independent functions. Connectable elements are, for example, emergency call buttons and handles, patient sockets without a call or a cancel button.
  • Enables the connection of an LED signaling lamp.
  • Antibacterial surface (silver admixture in the plastic material)

Technical Specification

Dimensions: 82 x 82 x 23 mm

Weight: 135g

Power supply: 24V

Maximum power input: 1,8W